Electromagnetism lab – induction, transformer, generator

PhysicsElectric & Magnetic FieldsAges 17–18Virtual lab

Use with my class

Six experiment screens on electromagnetic induction: a bar magnet with a compass and a field meter; moving a magnet through a pickup coil to light a bulb (with electrons visibly flowing in the circuit); an electromagnet whose poles switch with a DC or AC supply; a transformer showing that the voltage ratio equals the turns ratio when both coils sit tightly on the core; a generator turned by flowing water, or a coil spinning in a uniform field with slip rings (AC) or a split-ring commutator (DC) and graphs of flux linkage and EMF; and a search coil turned in an alternating field, read on an oscilloscope with a results table. Adapted from the "Faraday's Electromagnetic Lab" and "Generator" simulations by PhET Interactive Simulations, University of Colorado Boulder (CC BY 4.0); rewritten and extended.

Lesson: Electromagnetic induction

What it shows

Electromagnetic induction happens whenever the flux linked with a coil changes: Faraday's law gives the induced EMF as the rate of change of flux linkage, and Lenz's law gives its direction. The screens build this up from a bar magnet, through a pickup coil, an electromagnet and a transformer, to generators. In the rotating-coil generator, flux linkage NΦ = NBA cos ωt and EMF ε = NBAω sin ωt are 90° out of phase; slip rings give AC and a commutator gives varying DC. The search coil screen tests that the peak EMF is proportional to cos θ. Fields are idealised and no current is drawn.

How to use

Choose a screen with the tabs. On Generator, pick a Generator type: the rotating coil types draw NΦ and ε against time, so change Turns N, Flux density B, Coil area A and Angular speed ω, and press Pause to read values. On Search coil, set the Angle θ, choose a Y-gain that keeps the trace on screen, press Record, and repeat at several angles to plot ε₀ against cos θ.

Parameters you can change

  • Screen Bar magnet, Pickup coil, Electromagnet, Transformer, Generator, Search coil
  • Magnet strength (Bar magnet, Pickup coil) 0–100 %
  • Show magnetic field vector grid
  • Show compass (Bar magnet)
  • Show field meter (Bar magnet)
  • Magnetic field display units Gauss (G), Tesla (T)
  • Pickup coil turns 1–8 turns
  • Pickup coil radius 1.5–4 cm
  • Magnet's left pole (Pickup coil) North (N) on the left, South (S) on the left
  • Indicator (Pickup coil) Bulb, Voltmeter
  • Electromagnet turns 1–8 turns
  • Power supply type (Electromagnet) Direct current (DC), Alternating current (AC)
  • DC supply voltage -6–6 V
  • AC supply amplitude (Electromagnet) 0–6 V
  • AC supply frequency (Electromagnet) 0.1–1 Hz
  • Iron core (Electromagnet)
  • Primary coil turns (Transformer) 2–10 turns
  • Secondary coil turns (Transformer) 2–16 turns
  • Primary voltage amplitude U1 (Transformer) 1–6 V
  • AC supply frequency (Transformer) 0.1–1 Hz
  • Secondary indicator (Transformer) Bulb, Voltmeter
  • Water flow (Generator) 0–100 %
  • Coil turns (Generator) 1–6 turns
  • Magnet strength (Generator) 20–100 %
  • Indicator (Generator) Bulb, Voltmeter
  • Generator type (Generator) Rotating magnet driven by water, Rotating coil with slip rings (AC), Rotating coil with split-ring commutator (DC)
  • Coil turns N (Generator, rotating coil) 10–200 turns
  • Magnetic flux density B (Generator, rotating coil) 0.05–0.5 T
  • Coil area A (Generator, rotating coil) 10–100 cm²
  • Angular speed ω (Generator, rotating coil) 1–12 rad/s
  • Angle θ between search coil axis and field (Search coil) 0–90 °
  • Search coil turns N 500–5000 turns
  • Field coil r.m.s. current I (Search coil) 0.5–3 A
  • AC frequency f (Search coil) 10–100 Hz
  • Oscilloscope Y-gain (Search coil) 0.01 V/div, 0.02 V/div, 0.05 V/div, 0.1 V/div, 0.2 V/div, 0.5 V/div

Questions to explore

  1. Why is the EMF zero at the moment when the flux linkage through the rotating coil is greatest?
  2. How does doubling the angular speed ω change the peak EMF and the period of the output?
  3. Which graph of the search coil readings shows that the peak EMF is proportional to cos θ?