Air pollutants from burning fuels – catalytic converters and flue-gas desulfurisation

ChemistryApplied & Practical ChemistryAges 16–17

Use with my class

An engine, power-station and atmosphere model. Choose petrol, diesel or sulfur-containing coal, set the oxygen supply λ and the flame temperature, and read the carbon monoxide, soot, unburnt hydrocarbons, NOₓ and SO₂ produced per kilogram of fuel. Switch on a Pt/Pd/Rh catalytic converter, low-sulfur fuel or flue-gas desulfurisation to see the emissions fall, with balanced equations, effects (toxic gas, acid rain, global dimming, respiratory illness) and a results table. A second screen, the flue-gas clean-up line, sends the coal power station's flue gas through an SCR catalyst, an electrostatic precipitator or fabric filter and a wet limestone scrubber, and records the inlet and outlet concentrations of each device for each setting.

Lesson: Air pollutants from fuels: incomplete combustion, NOₓ, SO₂, acid rain, catalytic converters and flue-gas desulfurisation

What it shows

Burning fuels releases more than carbon dioxide and water. Without enough oxygen, combustion gives toxic carbon monoxide, soot and unburnt hydrocarbons; hot flames turn nitrogen from the air into NOₓ, and sulfur in the fuel burns to SO₂, both causes of acid rain. A three-way catalytic converter cleans car exhaust only near λ = 1. A coal power station needs a line of devices: an SCR catalyst that turns NOₓ into nitrogen with ammonia, an electrostatic precipitator or fabric filter that catches over 99 % of the dust, and a limestone scrubber that removes SO₂. None of them removes CO₂.

How to use

Choose a Fuel, drag Oxygen supply λ and Flame temperature, and compare the faded and solid bars after ticking Catalytic converter, Low-sulfur fuel or FGD; Record result builds a table. Press Flue-gas clean-up line, choose a Dust filter and set the SCA, the ammonia and the limestone slurry: the graph and the table show the concentration after each device. Record these readings adds a row.

Parameters you can change

  • Fuel Petrol (modelled as octane, C₈H₁₈), Diesel (modelled as dodecane, C₁₂H₂₆), Coal containing sulfur (power station)
  • Oxygen supply λ (relative to the amount needed for complete combustion) 0.6–2
  • Flame temperature at λ = 1 1000–2400 °C
  • Use low-sulfur fuel
  • Fit a catalytic converter (petrol and diesel vehicles)
  • Switch on flue-gas desulfurisation, FGD (coal power station)
  • Screen Fuels and engines, Flue-gas clean-up line
  • Dust filter None, Electrostatic precipitator, Fabric filter (baghouse)
  • ESP plate area per gas flow (SCA) 10–150 s/m
  • Ammonia for the SCR catalyst (mol NH₃ per mol NOₓ) 0–1.2
  • Limestone slurry flow in the scrubber 0–150 % of design

Questions to explore

  1. Why does reducing the oxygen supply increase CO and soot but decrease NOₓ?
  2. Why does a three-way catalytic converter remove NOₓ only when λ is very close to 1?
  3. How many grams of SO₂ come from burning 1 kg of coal containing 2.5 % sulfur?
  4. Why does a fabric filter let less fine dust (PM2.5) through than an electrostatic precipitator?